Burner Controls
»
Ignition Systems
FGI 202
The FGI 202 is a Flame-Gard™ Ignition system for atmospheric burners. Using a type K thermocouple, it monitors the pilot flame, takes action to stop the flow of fuel gas if the pilot flame fails, and brings the fuel gas on in an orderly manner when the system is commanded to restart (auto or manual operation). The DC Voltage Spark Generator with Spark Electrode supplies the ignition spark. Includes Burner push button ESD and flame fail dry contacts. It offers the same benefits as the FGI 201.
INTENDED FOR DUAL BURNER APPLICATIONS
Engineering Bulletin: FGI 100/201/202, IGN 11/12/14 Burner Controls
Features:
- Compact fiberglass enclosures with Switch Pad Front Panel
- Enclosures CSA & NRTL/C approved for Class I Div II
- Redefined input power - 12 or 24 VDC, 9 or 18 VAC
- Thermocouple based system (type K encased in 466 SS)
- DC voltage Spark Generator with Spark electrode included
- Auto re-light or Manual operation
- Push button for ESD shut-down
- Flame fail contacts (dry) supplied for flame fail alarm
- Solenoid status VFD (Vacuum Fluorescent Display) on front panel
- Remote start / remote stop control standard features
- RUN / SERVICE' mode for field testing and start up
- Large, easily accessible field termination
- Pilot signal on front panel
- Two trip point action with an atmospheric purge cycle
- Trip levels are adjustable with on board trim pots
- Supports continuous current solenoids or the Skinner Magnalatch solenoids (PULSE OPEN / PULSE CLOSED)
- -40 °C to +60 °C operating range with no internal heater required
- Very low power consumption. Less than 1/5th of one Watt when using Skinner Magnalatch solenoids
- All circuits are transient protected and are fail safe
Applications:
- Dehydrators
- Separators
- Line heater
- Heated Tanks